Sign In | Join Free | My hardware-wholesale.com
China Xi'an Xigao Electricenergy Group Co., Ltd. logo
Xi'an Xigao Electricenergy Group Co., Ltd.
Xi'an Xigao Electricenergy Group Co., Ltd.
Verified Supplier

5 Years

Home > Air Load Break Switch >

10KV Indoor Gas Insulated Air Load Break Switch With Fuse

Xi'an Xigao Electricenergy Group Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

10KV Indoor Gas Insulated Air Load Break Switch With Fuse

  • 1
  • 2
  • 3

Brand Name : XG

Model Number : FZN21

Certification : ISO,CCC

Place of Origin : XIAN

MOQ : 1 SET

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 2000 SETS

Delivery Time : 3-7 DAYS

Packaging Details : WOODEN CASE

Function : Switch on and off normal load current

Installation Location : power plants, substations and power systems etc

Warranty : 12 months

OEM : Yes

Package : exporting standard package

MOQ : 1set

Operation type : electric or manual

Contact Now

1.FZN21-12KV 11KV 10KV indoor Gas Insulated Air Load Break Switch

FZN21-12(R)D/T125-31.5 Series Indoor AC high voltage load switch- fuse combination units appliances for three-phase AC 10kV, 50Hz power system, or with the complete power distribution equipment and loop-network switch cabinet , combined substation and other ancillary uses, is widely used in urban network construction and transformation engineering, industrial and mining enterprises, high-rise buildings and public facilities ,can be used as ring power supply unit or terminal equipment, play power distribution, control and protection.

Technical performance of the products meet the IEC publication 60265-1/FDIS “high voltage switches, Part 1: Rated voltages below 1kV over 52kV high voltage load switch”, IEC60420 “High Voltage AC load switch – fuse combination units”; and CB16926 “AC High-voltage load switch - fuse combination units”, GB3804 “3-63kV AC high voltage switches” requirement.

2.Product parameter data

No Item Unit Value
1 Rated voltage kV 12
2 Rated frequency Hz 50
3 Rated current A 630 125
4 Rated insulation level 1min power frequency withstand voltage kV Arc-quenching chamber fracture 48
(effective value) Earth , phase 42, insulating fracture 48
Lightning impulse withstand voltage (peak) Earth , phase 75, insulating fracture 85
5 Rated dynamic current (peak) kA 50
6 4S thermal current kA 20
7 Rated power load breaking current A 630
8 Rated closed-loop breaking current A 630
9 Rated cable charge breaking current A 10
10 Rated breaking no-load transformer capacity KVA 1250
11 Rated breaking AC current A 3150
12 Rated short-circuit closed current kA 50
13 Rated current breaking times times 2000
14 Mechanical life times 10000
15 Permitted wear-thickness of vacuum arc-quenching chamber contact mm 2
16 Manual operating torque Nm >200

3.Environmental application

A. The ambient air temperature: Max.: +40 °C. Min: -10 °C.

B. The altitude ≤ 1000m.

C. The relative humidity of air. daily average ≤ 90%. monthly average ≤ 95%.

D. The ambient air should not be obviously polluted by corrosively or the flammability gas and gleam. etc.

E. Without frequent shake.

F. Environment degree: grade Ⅱ.

4.Technical diagram

10KV Indoor Gas Insulated Air Load Break Switch With Fuse

5.Warehouse view

10KV Indoor Gas Insulated Air Load Break Switch With Fuse


Product Tags:

Insulated Air Load Break Switch

      

10KV Air Load Break Switch

      

OEM Air Load Break Switch

      
China 10KV Indoor Gas Insulated Air Load Break Switch With Fuse wholesale

10KV Indoor Gas Insulated Air Load Break Switch With Fuse Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Xigao Electricenergy Group Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)